Scope
For SpycerNodes SNO2U and SNO5U.
Replacing defective disk drive with same exact model.
Condition
A failed disk drive is reported as seen by mmhealth node show
:
Procedure
Replace the drive per this instruction (for SNO5U):
https://support.dvsus.com/hc/en-us/articles/4417905127060-SpycerNode-5U-drive-replacement-video
After the physical drive replacement, launch the IBM GUI and initiate the fix procedure:
https://support.dvsus.com/hc/en-us/articles/360044138431-GPFS-IBM-Spectrum-Scale-GUI-login
From the Home page, click on the orange value which represents the failed disk:
Highlight the entry of the unhealthy pdisk list, right click and select Replace Disk:
Click Next, disregard the "Do not replace the disk yet!" statement:
Click Next, disregard the "Do not replace the disk yet!" statement:
Select "The disk has been replaced." > Finish:
It will take a couple of minutes but you will get this confirmation:
Confirmation
Rebuild in-progress, health status will be updated within a couple of minutes:
The GUI will update and show no faulty disks, GUI update is a little laggy, takes about 30 minutes:
From:
To:
0 Comments